The Fluke 1621 ground resistance meter offers basic methods for measuring ground resistance, such as the three-wire potential drop method and the two-wire ground resistance method. The ground resistance meter has a compact design, its robust case and its wide and clear LCD screen make it the ideal instrument for checking ground resistance for most work environments. The handling of the ground resistance meter makes it a practical tool for electricians, installation engineers, and ground resistance measurement specialists.

- 3-wire potential drop method for basic measurements 

- Ground resistance measurements with 2 wires for greater versatility 

- Easy value capture with just a button press 

- Guaranteed precision measurements thanks to automatic detection of electrical noise 

- The warning function for dangerous voltages provides added safety for the user 

- Large backlit display that allows easy reading and recording of data 

- Robust design and durable casing for the most adverse working environments 

- Its manageable size allows for easy transport 

- Thanks to the ability to adjust the working limits, the equipment alerts you of the measurements that

  they are outside of those limits 600 V Cat II

Technical specifications

Measurement functions

Ground resistance of 3 wires, resistance of a conductor in AC systems to 2 wires, interference voltage

Intrinsic error

Indicates the reference temperature range and is guaranteed for one year

Measurement speed

2 medidas/segundo

Battery

1 x 9 V alkaline battery (LR61)

Battery conditions

LO-BAT appears when the battery voltage drops below 6.5 V

Tensiones

- Between the H/C2 and E/C1 pins: 250 Veff

   maximum (effective voltage)

- Between the pins S/P2 and E/C1: 250 Veff

   maximum

Climate class

VDE/VDI 3540 RZ (in accordance with KWG according to DIN 40040, 4/87)

Thermal features

Operating range: -10 °C to +50 °C 

Operating range: -0 °C to +35 °C

Storage: -20 °C to +60 °C

Reference: +23 °C ± 2 °C

Thermal coefficient

± 0.1 % of range per degree Kelvin

Seguridad

IEC/EN 61010-1, 600 V CAT II, pollution degree 2

Dimensions

113 x 54 x 216 mm (incluida la funda)

Peso

850 g (including standard accessories)

Electrical specifications

Maximum deviations

Influence factor E1: Position

Deviation influence E1: 0%

Influence factor E2: Supply voltage

Deviation influence E2: 0%

Influence factor E3: Temperature E3

Deviation influence E3: 2.3%

Influence factor E4: Series interference voltage (20 V)

Deviation influence E4: 0.6 %

Influence factor E5: Probe resistance and auxiliary probe resistance

Deviation influence E5: 100%

Test voltages

3,7 kV

Protection class

IP 40; IEC/EN 60529

Electromagnetic compatibility

Emission: IEC/EN 61326 Class B

Inmunidad: IEC/EN 61326 Anexo C

Measurement of ground resistance (RE)

Measurement method: Measurement of voltage and current with improved crosstalk attenuation, without compensation for the resistance of the measuring cable, with probe (3 wires) or without probe (2 wires), according to IEC/EN 61557-5

Open circuit voltage: 23 to 24 V AC

Short-circuit current: >50 mA AC

Measurement frequency: 128 Hz

Max. allowed overload: 250 Veff

Measurement time

8 seconds (average after pressing START)

Limit input

The tester retains the settings even when turned off (as long as the battery is operational)

Automatic resolution change

RH: < 7 kΩ

Resolution: 0,01 Ω

RH: < 50 kΩ

Resolution: 0,1 Ω

RH: < 50 kΩ

Resolution: 1 Ω

DC + AC interference voltage display

V max.: 30 Veff

Common mode suppression: > 80 dB at 50 Hz and 60 Hz

Ri: 680 kΩ

Measurement uncertainty: < 10% for pure AC and DC signals

Measurement range

From 0.15 Ω to 20 Ω

Resolution: 0,01 Ω

Range: 0 a 19,99 Ω

200 Ω

Resolution: 0,1 Ω

Range: 20 a 199,9 Ω

2 kΩ

Resolution: 1 Ω

Range: 200 a 1999 Ω

Intrinsic uncertainty

± (6% of the measured value + 5D)

Operational uncertainty IEC 61557

± (18% of the measured value + 5D)

Contents of the shipment

1 x Earth resistance meter Fluke 1621

2 x Test leads with alligator clips (2 m)

1 x 9 V alkaline battery (LR61)

1 x Funda protectora

1 x CD-ROM with instruction manual

More information:               

Metrological calibration certificate of:

Technical service and maintenance of:
Earth meter Earth meter
Certificado de calibración CAL-LCR
International calibration certificate:    220 US$ Preventive maintenance and verification:   35 US$
Calibration certificate from EQUINLAB SAC calibration laboratory - Standard 17025 30 US$ Repair, corrective maintenance, adjustment, update, and validation:                       60 US$

Includes:
** 2-year warranty.
** Discounts for the sale of two or more Earth meter.
** Metrological calibration certificate for Earth meter.
** Preventive maintenance, corrective (repair), technical service, and spare parts.
** Sales, maintenance, calibration, certification, and technical service 24 hours.
Envios a: Argentina, Bolivia, Brasil, Chile, Colombia, Costa, Rica, Cuba, Ecuador, El Salvador, Guatemala, Honduras, Mexico, Nicaragua, Panama, Paraguay, Peru, Puerto Rico, Dominican Republic, Uruguay, Venezuela.
Quick contact:     Ventas@equinlabsac.live mail     info@equinlabsac.live mail

 

Price: $ 1,230.00