Fluke 1630 earth resistance meter with clamp for measuring without spikes, for portable use
The Fluke 1630 ground resistance meter simplifies the process of checking ground loops and allows for non-intrusive leakage current measurements. The ground resistance meter uses the test method without stakes, eliminating the need to disconnect parallel ground systems and find suitable places to place auxiliary stakes. The compact and rugged design of the Fluke 1630 makes it easy to use in small spaces and the most demanding work environments, while the screen value hold and acoustic alarm functions for continuity checking ensure greater user comfort. This new technique allows for ground loop and continuity checking without the need to open the circuit.
- A wide range of ground loop resistances, from 0.025 Ω to 1500 Ω, to provide
respuesta a todas sus necesidades.
- Wide opening of the 35 mm jaws for measuring ground conductors and/or bars
colectoras equipotenciales.
- Measurement of ground leakage current, from 0.2 mA to 1,000 mA, no need for
disconnect, making it ideal for detecting problems in systems.
- Wide range of AC measurements from 0.2 A to 30 A allowing the use of a single
Instrument for multiple applications.
- User-defined high and low alarm value limits for quick evaluation of the
medidas.
- Useful hold button to capture readings in inaccessible places.
- The memory function saves time as it automatically records and stores logs
the values of the measurements taken.
- Automatic self-calibration to always ensure precise and reliable measurements
- Overload protection: 200 A
- Transport case and resistance measurement loop included
- ≥ 8 hours battery life (in continuous operation)
Specifications generales
Operating error
Refers to the operating temperature range and has a 2-year warranty
Storage temperature range
-20 ... 60 ºC
Reference temperature range
23 °C ± 5 °C
Storage humidity
<75 % H.r.
Operating humidity
<85 % H.r.
Pantalla
Digital LC screen 999 with special symbols
Protection
IP30 according to IEC 529/EN 60529
Seguridad
300 V, CAT III pollution degree 2, IEC 61010-1 and IEC 61010-2-032
Peso
750 g
Conductor size
35 mm aprox.
Dimensions
276 x 100 x 47 mm (incluida la funda)
Emisiones
IEC 1000 4-2, IEC 61326-I clase B
Inmunidad
IEC 61000-4-2, 8 kV (aire) criterios A
IEC 61000-4-3, 3 V/m performance criteria A
Range selection
Auto
Overload indicator
"OL" on the display
Measurement time
0,5 seg.
Measurement frequency
3,333 kHz
Battery type
9 V alcalina (tipo IEC 6 LR61)
Battery life
≥ 8 horas (en continuo funcionamiento)
Electric consumption
40 mA
Battery indicator
Baja
Ground loop resistance (automatic range selection)
Rango
Accuracy (± % of Ω reading)
0,025 - 0,250 Ω
± 1,5 % lectura ± 0,02 Ω
0,250 - 9,999 Ω
± 1,5 % lectura ± 0,05 Ω
10 - 99,99 Ω
± 2 % lectura ± 0,3 Ω
100 - 199,9 Ω
± 3 % lectura ± 1 Ω
200 - 400 Ω
± 5 % lectura ± 5 Ω
400 - 600 Ω
± 10 % lectura ± 10 Ω
600 - 1500 Ω
± 20 %
Contents of the shipment
1 x Fluke 1630 ground resistance meter
1 x Sturdy case with shoulder strap
1 x Test leads with alligator clips (2 m)
1 x 9 V alkaline battery (LR61)
1 x Instruction Manual
Information:
Recommendation:
Metrological calibration certificate of:
Technical service and maintenance of:
Grounding meter
Grounding meter
International calibration certificate:
220 US$
Preventive maintenance and verification:
35 US$
Calibration certificate from EQUINLAB SAC calibration laboratory - Standard 17025
30 US$
Repair, corrective maintenance, adjustment, update, and validation:
60 US$
Includes:
** 2-year warranty.
** Discounts for the sale of two or more Grounding meter .
** Metrological calibration certificate for Grounding meter .
** Preventive maintenance, corrective (repair), technical service, and spare parts.
** Sales, maintenance, calibration, certification, and technical service 24 hours.
Envios a:Argentina, Bolivia, Brasil, Chile, Colombia, Costa, Rica, Cuba, Ecuador, El Salvador, Guatemala, Honduras, Mexico, Nicaragua, Panama, Paraguay, Peru, Puerto Rico, Dominican Republic, Uruguay, Venezuela.