Fluke 1621 ground resistance meter for portable use
The Fluke 1621 ground resistance meter offers basic methods for measuring ground resistance, such as the three-wire potential drop method and the two-wire ground resistance method. The ground resistance meter has a compact design, its robust case and its wide and clear LCD screen make it the ideal instrument for checking ground resistance for most work environments. The handling of the ground resistance meter makes it a practical tool for electricians, installation engineers, and ground resistance measurement specialists.
- 3-wire potential drop method for basic measurements
- Ground resistance measurements with 2 wires for greater versatility
- Easy value capture with just a button press
- Guaranteed precision measurements thanks to automatic detection of electrical noise
- The warning function for dangerous voltages provides added safety for the user
- Large backlit display that allows easy reading and recording of data
- Robust design and durable casing for the most adverse working environments
- Its manageable size allows for easy transport
- Thanks to the ability to adjust the working limits, the equipment alerts you of the measurements that
they are outside of those limits 600 V Cat II
Technical specifications
Measurement functions
Ground resistance of 3 wires, resistance of a conductor in AC systems to 2 wires, interference voltage
Intrinsic error
Indicates the reference temperature range and is guaranteed for one year
Measurement speed
2 medidas/segundo
Battery
1 x 9 V alkaline battery (LR61)
Battery conditions
LO-BAT appears when the battery voltage drops below 6.5 V
Tensiones
- Between the H/C2 and E/C1 pins: 250 Veff
maximum (effective voltage)
- Between the pins S/P2 and E/C1: 250 Veff
maximum
Climate class
VDE/VDI 3540 RZ (in accordance with KWG according to DIN 40040, 4/87)
Thermal features
Operating range: -10 °C to +50 °C
Operating range: -0 °C to +35 °C
Storage: -20 °C to +60 °C
Reference: +23 °C ± 2 °C
Thermal coefficient
± 0.1 % of range per degree Kelvin
Seguridad
IEC/EN 61010-1, 600 V CAT II, pollution degree 2
Dimensions
113 x 54 x 216 mm (incluida la funda)
Peso
850 g (including standard accessories)
Electrical specifications
Maximum deviations
Influence factor E1: Position
Deviation influence E1: 0%
Influence factor E2: Supply voltage
Deviation influence E2: 0%
Influence factor E3: Temperature E3
Deviation influence E3: 2.3%
Influence factor E4: Series interference voltage (20 V)
Deviation influence E4: 0.6 %
Influence factor E5: Probe resistance and auxiliary probe resistance
Deviation influence E5: 100%
Test voltages
3,7 kV
Protection class
IP 40; IEC/EN 60529
Electromagnetic compatibility
Emission: IEC/EN 61326 Class B
Inmunidad: IEC/EN 61326 Anexo C
Measurement of ground resistance (RE)
Measurement method: Measurement of voltage and current with improved crosstalk attenuation, without compensation for the resistance of the measuring cable, with probe (3 wires) or without probe (2 wires), according to IEC/EN 61557-5
Open circuit voltage: 23 to 24 V AC
Short-circuit current: >50 mA AC
Measurement frequency: 128 Hz
Max. allowed overload: 250 Veff
Measurement time
8 seconds (average after pressing START)
Limit input
The tester retains the settings even when turned off (as long as the battery is operational)
Automatic resolution change
RH: < 7 kΩ
Resolution: 0,01 Ω
RH: < 50 kΩ
Resolution: 0,1 Ω
RH: < 50 kΩ
Resolution: 1 Ω
DC + AC interference voltage display
V max.: 30 Veff
Common mode suppression: > 80 dB at 50 Hz and 60 Hz
Ri: 680 kΩ
Measurement uncertainty: < 10% for pure AC and DC signals
Measurement range
From 0.15 Ω to 20 Ω
Resolution: 0,01 Ω
Range: 0 a 19,99 Ω
200 Ω
Resolution: 0,1 Ω
Range: 20 a 199,9 Ω
2 kΩ
Resolution: 1 Ω
Range: 200 a 1999 Ω
Intrinsic uncertainty
± (6% of the measured value + 5D)
Operational uncertainty IEC 61557
± (18% of the measured value + 5D)
Contents of the shipment
1 x Earth resistance meter Fluke 1621
2 x Test leads with alligator clips (2 m)
1 x 9 V alkaline battery (LR61)
1 x Funda protectora
1 x CD-ROM with instruction manual
Information:
Recommendation:
Metrological calibration certificate of:
Technical service and maintenance of:
Grounding meter
Grounding meter
International calibration certificate:
220 US$
Preventive maintenance and verification:
35 US$
Calibration certificate from EQUINLAB SAC calibration laboratory - Standard 17025
30 US$
Repair, corrective maintenance, adjustment, update, and validation:
60 US$
Includes:
** 2-year warranty.
** Discounts for the sale of two or more Grounding meter .
** Metrological calibration certificate for Grounding meter .
** Preventive maintenance, corrective (repair), technical service, and spare parts.
** Sales, maintenance, calibration, certification, and technical service 24 hours.