Temperature Laboratory

$ 32.00
  • Equipment: Thermometer
  • Model:  Digital and Analogue
  • Range: -100°C to 2000°C
  • Delivery: 1 to 2 days
  • Traceability: INACAL, NIST, CENAM, OIML, BIPM, SIM, ENAC, CEM

 

For thermometer calibration by the comparison method, a thermometer of adequate resolution and previously calibrated with reference to the 1990 International Temperature Scale, EIT-90, is used as a standard. It is recommended to use a digital thermometer with a platinum resistance probe of the PT 100 type, accompanied by a calibration certificate issued by an INACAL laboratory or an International Laboratory, NIST, CENAM, OIML, BIPM ILAC, SIM, CEM, ENAC.

See Calibration   

 

$ 30.00
  • Equipment: Thermocouple 
  • Model:  pt100,1000,E,J,K,S,T,N,B,R
  • Range: -100°C to 2000°C
  • Delivery: 1 to 2 days
  • Traceability: INACAL, NIST, CENAM, OIML, BIPM, SIM, ENAC, CEM

 

For thermocouple calibration by the comparison method, a thermometer of adequate resolution and previously calibrated with reference to the 1990 International Temperature Scale, EIT-90, is used as a standard. It is recommended to use a digital thermometer with a platinum resistance probe of the PT 100 type, accompanied by a calibration certificate issued by an INACAL laboratory or an International Laboratory, NIST, CENAM, OIML, BIPM ILAC, SIM, CEM, ENAC.

See Calibration   

 

$ 50.00
  • Equipment: incubators
  • Model: Analog / digital
  • Range: -20°C to 150°C
  • Volume: 15- 2000 liters
  • Certificate delivery: 1 day
  • Traceability: INACAL, NIST, CENAM, OIML, BIPM, SIM, ENAC, CEM

 

For the calibration of incubators by the comparison method, a thermometer of adequate resolution and previously calibrated with reference to the 1990 International Temperature Scale, EIT-90, is used as a standard. It is recommended to use a digital thermometer with at least 12 platinum resistance probes of the PT 100 or temocouple type, accompanied by a calibration certificate issued by an INACAL laboratory or an International Laboratory, NIST, CENAM, OIML, BIPM ILAC, SIM, CEM, ENAC.

See Calibration   

 

$ 50.00
  • Equipment: Stove
  • Model: Analog / digital
  • Range: -20°C to 150°C
  • Volume: 15- 2000 liters
  • Certificate delivery: 1 day
  • Traceability: INACAL, NIST, CENAM, OIML, BIPM, SIM, ENAC, CEM

 

The calibration of Stoves by the comparison method uses as a standard a thermometer of adequate resolution and previously calibrated with reference to the 1990 International Temperature Scale, EIT-90. It is recommended to use a digital thermometer with at least 12 platinum resistance probes of the PT 100 or temocupla type, accompanied by a calibration certificate issued by an INACAL laboratory or an International Laboratory, NIST, CENAM, OIML, BIPM ILAC, SIM, CEM, ENAC.

See Calibration

 

$ 40.00
  • Equipment: Autoclave
  • Model: Analog / digital
  • Range: -20°C to 150°C
  • Volume: 15- 2000 liters
  • Certificate delivery: 1 day
  • Traceability: INACAL, NIST, CENAM, OIML, BIPM, SIM, ENAC, CEM

 

Autoclave calibration by the comparison method uses as a standard a thermometer of adequate resolution and previously calibrated with reference to the 1990 International Temperature Scale, EIT-90. It is recommended to use a digital thermometer with at least 12 platinum resistance probes of the PT 100 or temocupla type, accompanied by a calibration certificate issued by an INACAL laboratory or an International Laboratory, NIST, CENAM, OIML, BIPM ILAC, SIM, CEM, ENAC.

See Calibration

 

$ 30.00
  • Equipment: Ovens
  • Model: Analog / digital
  • Range: 20°C to 2000°C
  • Volume: 15- 2000 liters
  • Certificate delivery: 1 day
  • Traceability: INACAL, NIST, CENAM, OIML, BIPM, SIM, ENAC, CEM

 

The calibration of Furnaces by the comparison method uses as a standard a thermometer of adequate resolution and previously calibrated with reference to the 1990 International Temperature Scale, EIT-90. It is recommended to use a digital thermometer with at least 1 to 2 platinum resistance probes of the PT 100 or temocouple type, accompanied by a calibration certificate issued by an INACAL laboratory or an International Laboratory, NIST, CENAM, OIML, BIPM ILAC, SIM, CEM, ENAC.

See Calibration

 

$ 40.00
  • Equipment: Bain Marie
  • Model: Analog / digital
  • Range: 20°C to 100°C
  • Volume: 15- 200 liters
  • Certificate delivery: 1 day
  • Traceability: INACAL, NIST, CENAM, OIML, BIPM, SIM, ENAC, CEM

 

The Bain-marie calibration by the comparison method uses as a standard a thermometer of adequate resolution and previously calibrated with reference to the 1990 International Temperature Scale, EIT-90. It is recommended to use a digital thermometer with at least 12 platinum resistance probes of the PT 100 or temocupla type, accompanied by a calibration certificate issued by an INACAL laboratory or an International Laboratory, NIST, CENAM, OIML, BIPM ILAC, SIM, CEM, ENAC.

See Calibration

 

$ 50.00
  • Equipment: Refrigerator
  • Model: Analog / digital
  • Range: 20°C to 100°C
  • Volume: 15- 200 liters
  • Certificate delivery: 1 day
  • Traceability: INACAL, NIST, CENAM, OIML, BIPM, SIM, ENAC, CEM

 

The Refrigerator calibration by the comparison method uses as a standard a thermometer of adequate resolution and previously calibrated with reference to the 1990 International Temperature Scale, EIT-90. It is recommended to use a digital thermometer with at least 12 platinum resistance probes of the PT 100 or temocupla type, accompanied by a calibration certificate issued by an INACAL laboratory or an International Laboratory, NIST, CENAM, OIML, BIPM ILAC, SIM, CEM, ENAC.

See Calibration